mirror of
https://github.com/ZGCA-Forge/Elevator.git
synced 2025-12-19 05:51:05 +00:00
Update docs (Energy)
This commit is contained in:
@@ -65,6 +65,8 @@ Response format:
|
|||||||
"passengers": [101, 102],
|
"passengers": [101, 102],
|
||||||
"max_capacity": 10,
|
"max_capacity": 10,
|
||||||
"run_status": "constant_speed",
|
"run_status": "constant_speed",
|
||||||
|
"energy_consumed": 38.5,
|
||||||
|
"energy_rate": 1.0,
|
||||||
"..."
|
"..."
|
||||||
}
|
}
|
||||||
],
|
],
|
||||||
@@ -81,7 +83,8 @@ Response format:
|
|||||||
"avg_wait": 15.2,
|
"avg_wait": 15.2,
|
||||||
"p95_wait": 30.0,
|
"p95_wait": 30.0,
|
||||||
"avg_system": 25.5,
|
"avg_system": 25.5,
|
||||||
"p95_system": 45.0
|
"p95_system": 45.0,
|
||||||
|
"total_energy_consumption": 156.0
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
|
|||||||
@@ -28,7 +28,9 @@ Features
|
|||||||
|
|
||||||
🔌 **Client-Server Model**: Separate simulation server from control logic for clean architecture
|
🔌 **Client-Server Model**: Separate simulation server from control logic for clean architecture
|
||||||
|
|
||||||
📊 **Performance Metrics**: Track wait times, system times, and completion rates
|
📊 **Performance Metrics**: Track wait times, system times, completion rates, and energy consumption
|
||||||
|
|
||||||
|
⚡ **Energy Tracking**: Monitor and optimize energy consumption with configurable per-elevator energy rates
|
||||||
|
|
||||||
🎯 **Flexible Control**: Implement your own algorithms using a simple controller interface
|
🎯 **Flexible Control**: Implement your own algorithms using a simple controller interface
|
||||||
|
|
||||||
|
|||||||
@@ -128,6 +128,7 @@ Complete state information for an elevator:
|
|||||||
indicators: ElevatorIndicators = field(default_factory=ElevatorIndicators)
|
indicators: ElevatorIndicators = field(default_factory=ElevatorIndicators)
|
||||||
passenger_destinations: Dict[int, int] = {} # passenger_id -> floor
|
passenger_destinations: Dict[int, int] = {} # passenger_id -> floor
|
||||||
energy_consumed: float = 0.0
|
energy_consumed: float = 0.0
|
||||||
|
energy_rate: float = 1.0 # Energy consumption rate per tick
|
||||||
last_update_tick: int = 0
|
last_update_tick: int = 0
|
||||||
|
|
||||||
Key Properties:
|
Key Properties:
|
||||||
@@ -142,6 +143,11 @@ Key Properties:
|
|||||||
- ``pressed_floors``: List of destination floors for current passengers
|
- ``pressed_floors``: List of destination floors for current passengers
|
||||||
- ``load_factor``: Current load as fraction of capacity (0.0 to 1.0)
|
- ``load_factor``: Current load as fraction of capacity (0.0 to 1.0)
|
||||||
|
|
||||||
|
Energy Tracking:
|
||||||
|
|
||||||
|
- ``energy_consumed``: Total energy consumed by this elevator during the simulation
|
||||||
|
- ``energy_rate``: Energy consumption rate per tick when moving (default: 1.0). Can be customized in traffic configuration files to simulate different elevator types (e.g., older elevators with higher rates, newer energy-efficient elevators with lower rates)
|
||||||
|
|
||||||
FloorState
|
FloorState
|
||||||
~~~~~~~~~~
|
~~~~~~~~~~
|
||||||
|
|
||||||
@@ -261,11 +267,16 @@ Tracks simulation performance:
|
|||||||
p95_floor_wait_time: float = 0.0 # 95th percentile
|
p95_floor_wait_time: float = 0.0 # 95th percentile
|
||||||
average_arrival_wait_time: float = 0.0
|
average_arrival_wait_time: float = 0.0
|
||||||
p95_arrival_wait_time: float = 0.0 # 95th percentile
|
p95_arrival_wait_time: float = 0.0 # 95th percentile
|
||||||
|
total_energy_consumption: float = 0.0 # Total energy consumed by all elevators
|
||||||
|
|
||||||
Properties:
|
Properties:
|
||||||
|
|
||||||
- ``completion_rate``: Fraction of passengers completed (0.0 to 1.0)
|
- ``completion_rate``: Fraction of passengers completed (0.0 to 1.0)
|
||||||
|
|
||||||
|
Energy Metrics:
|
||||||
|
|
||||||
|
- ``total_energy_consumption``: Sum of energy consumed by all elevators in the system. Each elevator consumes ``energy_rate`` units of energy per tick when moving.
|
||||||
|
|
||||||
API Models
|
API Models
|
||||||
----------
|
----------
|
||||||
|
|
||||||
@@ -345,3 +356,75 @@ All models support JSON serialization:
|
|||||||
restored = ElevatorState.from_dict(data)
|
restored = ElevatorState.from_dict(data)
|
||||||
|
|
||||||
This enables seamless transmission over HTTP between client and server.
|
This enables seamless transmission over HTTP between client and server.
|
||||||
|
|
||||||
|
Energy System
|
||||||
|
-------------
|
||||||
|
|
||||||
|
Overview
|
||||||
|
~~~~~~~~
|
||||||
|
|
||||||
|
The energy system tracks energy consumption of elevators to help optimize control algorithms for both passenger service and energy efficiency.
|
||||||
|
|
||||||
|
How Energy Works
|
||||||
|
~~~~~~~~~~~~~~~~
|
||||||
|
|
||||||
|
**Energy Consumption:**
|
||||||
|
|
||||||
|
- Each elevator has an ``energy_rate`` attribute (default: 1.0)
|
||||||
|
- When an elevator moves (any tick where it's not stopped), it consumes energy equal to its ``energy_rate``
|
||||||
|
- Energy consumption is independent of speed, direction, or load
|
||||||
|
- Total system energy is the sum of all individual elevator energy consumption
|
||||||
|
|
||||||
|
**Configuration:**
|
||||||
|
|
||||||
|
Energy rates are configured in traffic JSON files via the ``elevator_energy_rates`` field:
|
||||||
|
|
||||||
|
.. code-block:: json
|
||||||
|
|
||||||
|
{
|
||||||
|
"building": {
|
||||||
|
"floors": 10,
|
||||||
|
"elevators": 3,
|
||||||
|
"elevator_capacity": 10,
|
||||||
|
"elevator_energy_rates": [1.0, 1.0, 1.2],
|
||||||
|
"scenario": "custom_scenario",
|
||||||
|
"duration": 600
|
||||||
|
},
|
||||||
|
"traffic": []
|
||||||
|
}
|
||||||
|
|
||||||
|
In this example, elevators 0 and 1 have standard energy rates (1.0), while elevator 2 consumes 20% more energy (1.2), perhaps representing an older or less efficient unit.
|
||||||
|
|
||||||
|
**Use Cases:**
|
||||||
|
|
||||||
|
1. **Algorithm Optimization**: Balance passenger wait times against energy consumption
|
||||||
|
2. **Heterogeneous Fleets**: Model buildings with elevators of different ages/efficiencies
|
||||||
|
3. **Cost Analysis**: Evaluate the energy cost of different control strategies
|
||||||
|
4. **Green Building Simulation**: Optimize for minimal energy while maintaining service quality
|
||||||
|
|
||||||
|
Example Usage
|
||||||
|
~~~~~~~~~~~~~
|
||||||
|
|
||||||
|
.. code-block:: python
|
||||||
|
|
||||||
|
# Get current state
|
||||||
|
state = api_client.get_state()
|
||||||
|
|
||||||
|
# Check individual elevator energy
|
||||||
|
for elevator in state.elevators:
|
||||||
|
print(f"Elevator {elevator.id}: {elevator.energy_consumed} units consumed")
|
||||||
|
print(f" Energy rate: {elevator.energy_rate} units/tick")
|
||||||
|
|
||||||
|
# Check total system energy
|
||||||
|
metrics = state.metrics
|
||||||
|
print(f"Total system energy: {metrics.total_energy_consumption} units")
|
||||||
|
print(f"Completed passengers: {metrics.completed_passengers}")
|
||||||
|
|
||||||
|
# Calculate energy per passenger
|
||||||
|
if metrics.completed_passengers > 0:
|
||||||
|
energy_per_passenger = metrics.total_energy_consumption / metrics.completed_passengers
|
||||||
|
print(f"Energy per passenger: {energy_per_passenger:.2f} units")
|
||||||
|
|
||||||
|
**Default Behavior:**
|
||||||
|
|
||||||
|
If ``elevator_energy_rates`` is not specified in the traffic file, all elevators default to an energy rate of 1.0, ensuring backward compatibility with existing traffic files.
|
||||||
|
|||||||
Reference in New Issue
Block a user