移液站样例

本样例介绍如何配置和启动移液站设备,并执行基本操作如插入枪头等。

准备工作

设备配置文件

移液站设备的完整配置可在 test/experiments/plr_test.json 文件中找到。该配置文件采用平展结构,通过 type 字段区分物料和设备,并通过 parentchildren 字段实现层级关系。

配置文件示例片段:

{
  "nodes": [
        {
            "id": "PLR_STATION",
            "name": "PLR_LH_TEST",
            "parent": null,
            "type": "device",
            "class": "liquid_handler",
            "config": {},
            "data": {},
            "children": [
                "deck"
            ]
        },
    {
      "id": "deck",
      "name": "deck",
      "type": "container",
      "class": null,
      "parent": "PLR_STATION",
      "children": [
                "trash",
                "trash_core96",
                "teaching_carrier",
                "tip_rack",
                "plate"
            ]
    }
  ],
  "links": []
}

配置文件定义了移液站的组成部分,主要包括:

  • 移液站本体LiquidHandler- 设备类型
  • 移液站携带物料实例deck- 物料类型

启动方法

1. 启动移液站节点

使用以下命令启动移液站设备:

unilab -g test/experiments/plr_test.json --app_bridges ""

2. 执行枪头插入操作

启动后,您可以使用以下命令执行插入枪头操作:

ros2 action send_goal /devices/PLR_STATION/pick_up_tips unilabos_msgs/action/_liquid_handler_pick_up_tips/LiquidHandlerPickUpTips "{ tip_spots: [ { id: 'tip_rack_tipspot_0_0', name: 'tip_rack_tipspot_0_0', sample_id: null, children: [], parent: 'tip_rack', type: 'device', config: { position: { x: 7.2, y: 68.3, z: -83.5 }, size_x: 9.0, size_y: 9.0, size_z: 0, rotation: { x: 0, y: 0, z: 0, type: 'Rotation' }, category: 'tip_spot', model: null, type: 'TipSpot', prototype_tip: { type: 'HamiltonTip', total_tip_length: 95.1, has_filter: true, maximal_volume: 1065, pickup_method: 'OUT_OF_RACK', tip_size: 'HIGH_VOLUME' } }, data: { tip: { type: 'HamiltonTip', total_tip_length: 95.1, has_filter: true, maximal_volume: 1065, pickup_method: 'OUT_OF_RACK', tip_size: 'HIGH_VOLUME' }, tip_state: { liquids: [], pending_liquids: [], liquid_history: [] }, pending_tip: { type: 'HamiltonTip', total_tip_length: 95.1, has_filter: true, maximal_volume: 1065, pickup_method: 'OUT_OF_RACK', tip_size: 'HIGH_VOLUME' } } } ], use_channels: [ 0 ], offsets: [ { x: 0.0, y: 0.0, z: 0.0 } ] }"

此命令会通过ros通信触发移液站执行枪头插入操作得到如下的PyLabRobot的输出日志。

Picking up tips:
pip#  resource             offset           tip type     max volume (µL)  fitting depth (mm)   tip length (mm)  filter    
  p0: tip_rack_tipspot_0_0 0.0,0.0,0.0      HamiltonTip  1065             8                    95.1             Yes  

常见问题

  1. 重复插入枪头不成功操作编排应该符合实际操作顺序可自行通过PyLabRobot进行测试

移液站支持的操作

移液站支持多种操作,以下是当前系统支持的操作列表:

  1. LiquidHandlerAspirate - 吸液操作
  2. LiquidHandlerDispense - 排液操作
  3. LiquidHandlerDiscardTips - 丢弃枪头
  4. LiquidHandlerDropTips - 卸下枪头
  5. LiquidHandlerDropTips96 - 卸下96通道枪头
  6. LiquidHandlerMoveLid - 移动盖子
  7. LiquidHandlerMovePlate - 移动板子
  8. LiquidHandlerMoveResource - 移动资源
  9. LiquidHandlerPickUpTips - 插入枪头
  10. LiquidHandlerPickUpTips96 - 插入96通道枪头
  11. LiquidHandlerReturnTips - 归还枪头
  12. LiquidHandlerReturnTips96 - 归还96通道枪头
  13. LiquidHandlerStamp - 打印标记
  14. LiquidHandlerTransfer - 液体转移